| Mixer | Design volume | 20L |
| Working volume | 16L | |
| Low speed mixing system | Stirring power | 2.2KW |
| Revolution speed | 0-65rpm/min | |
| Rotational speed | 0-170rpm/min | |
| Mixing blade form | Spiral fried dough twists | |
| Material | 304 stainless steel | |
| High-speed decentralized system | Strong dispersion speed | 1400rpm/min (adjustable) |
| Distributed motor | 2.2KW | |
| Dispersion disk diameter | 60mm | |
| Material | 304 stainless steel | |
| Scraping the wall | Quantity | 1 group |
| Material | SUS304 and Teflon | |
| Speed | Consistent with the planetary revolution speed | |
| Lifting system | Power up and down | 0.55kw |
| Elevating height | Be pending | |
| Vacuum system | Vacuum power | 0.25kw |
| Vacuum degree | ≤-0.098Mpa | |
| Jacket | Double layered jacket, can be heated or cooled by water or oil | |
| Reason for malfunction | Troubleshooting | |
| Vacuum leak |
(1) The valve is not closed, and the vacuum valve for the pot lid is not open; (2) The sealing ring has been damaged, causing leakage; (3) The vacuum pump is not functioning properly. |
① Close all valves; ② Replace the sealing ring; ③ Please refer to the vacuum pump manual for maintenance of the vacuum pump. |
| The pump cannot generate vacuum |
(1) No working fluid; (2) Serious system leakage; (3) The rotation direction is incorrect. |
① Check the working fluid; ② Repair the leakage area; ③ Replace two wires and change the direction of rotation. |
| The motor does not start |
(1) At least two power cords are broken; (2) Motor bearing failure; (3) Homogeneous rotor sintering. |
① Check the wiring; ② Replace the motor bearings; ③ Check if the homogenizer rotor rotates flexibly and if there are foreign objects stuck in the homogenizer head or mixer. |
| When the motor starts, the current circuit breaker trips (motor overload) |
(1) Winding short circuit; (2) The homogeneous rotor sliding bearing is damaged; (3) The lifting shaft or lifting screw and lifting nut are damaged. |
① Check the motor winding (coil); ② Replace sliding bearings; ③ Adjust the coaxiality between the guide sleeve and the lifting column, replace the screw rod and screw nut. |
| There is a metallic sound when the scraper touches the pot during lifting or operation |
(1) Poor positioning (2) The scraper seat does not rotate flexibly and gets stuck in an inappropriate position. |
① Accurate positioning adjustment; ② Remove the dirt from the scraper seat and replace the pin shaft. |
| The oil in the vacuum pump enters the purifier and the pot | (3) When the vacuum pump is turned off, the vacuum pump on the purifier is not turned off. | ① Before turning off the vacuum pump, first close the vacuum valve on the purifier. |